Description: Set code C4, close the wheel guard and start an extended measuring run by lowering the wheel
guard. After the measuring run state switches automatically to 1, the adaptor symbol comes up and the mode is quit.
Resetting the state to 0 cancels compensation of adaptor unbalance.
Compensation is also cancelled by calibration, readjustment by the operator, an optimisation run or by turning o! the
machine.
Comments: None
C6 Number of revolutions for measurement
Options:
5 to 25 : Number of revolutions per measuring run
10 revs/run: Factory-adjusted value
Special function:None
Description:
WARNING! Reducing the number of measurement revolutions will reduce the accuracy of measurement.
Measurement accuracy can be evaluated using test mode C63.
The chosen mode of operation can be transferred to the permanent memory.
Comments: None
C7 Volume of audible signals
Options
0 to 100 : Volume (0 : low, 100 high)
50 : Factory-adjusted value
Special function: None
Description: The volume is not changed before the Acknowledgment key is pressed for quitting the mode.
The chosen mode of operation can be transferred to the permanent memory.
Comments: None.
C8 Treshold value of suppression of minor unbalance reading in units selected with C3
Options:
3.5 - 20g (0.12 - 0.71oz) : Threshold value
3.5g (0.12oz) : Factory-adjusted value
Special function: None
Description: To set a new value use the option selection. Finally press the Acknowledgment key to acknowledge
the entered value or press the Abort key to retain the former one.
To keep balance quality independent of weight placement, the OK indication is only visible if the unbalance readings
for the normal balancing mode (balance clips on rim fl anges) and the static unbalance are lower than the thresholds
set via C8. Therefore the rim width must be known for a correct assessment of the balance quality (and for
recommendation of optimisation).
If OK is displayed the unbalance readings will always be 0, irrespective of the selected balancing mode. If the
precision/FINE key is now pressed to disable the suppression of minor unbalance readings temporarily, this may result
in unbalance readings that are higher than the threshold in other than the normal balancing mode. This is due to the
fact that larger balance weights are usually required for adjacent correction planes and small diameters in the rim disc.
The threshold value can be transferred to the permanent memory.
Comments: The unit of measurement is chosen according to the one set with C3.