67
Comments: The asterisk “*“ marks the factory-adjusted default
C12 Recall counter - Only balancers with digital display
Options
(Only press the +/- key, do not turn the wheel)
1 : Total number of measuring runs
2 : Number of measuring runs where balance quality was considered OK
3 : Number of optimisations or minimisations
4 : Number of measuring runs in service mode
5 : Number of measuring runs since the last calibration
6 : Total number of clamping operations (p models only)
Special function: None
Description: Various counter readings.
Comments: This mode has been adjusted to usual sequences of operation.
C13 Starting measurement run by closing the wheel guard
Options:
0 : No start of measurement by closing the wheel guard
1* : Start of measurement by closing the wheel guard
Special function: None
Description: The chosen mode of operation can be transferred to the permanent memory.
Comments: The asterisk „*“ marks the factory-adjusted default.
C14 User calibration
Options : None
Special function: None
Description: Re-calibration serves to compensate for sensitivity losses of the transducers.
Mount adaptor without calibration weight, wheel, clamping nut, centring cone and spacer ring on the main shaft.
With power clamp, the small and medium centring cones and clamping sleeve without the clamping head to the
adaptor sleeve, and initiate the clamping operation.
Set code C14.
The following is displayed: CAL 1.
Lower the wheel guard to start the fi rst extended measuring run (twice as long as regular measuring run).
(Instantaneous compensation of residual unbalance.)
The following is displayed after the run: CAL 2.
Tighten the calibration weight inward of the adaptor " ange and lower the wheel guard to initiate the second extended
measuring run.
There is no third step as with the previous machine generations. Readjustment is completed after the measuring run
of step 2 and the corrective factors determined are saved automatically.
Remove calibration weight and place in storage location.
Comments: None