34
6. Others
6.1 Maintenance
Check whether the gate is operates normally every month.
For the sake of safety, each gate is suggested to be equipped with infrared protector, besides which
regular inspection is required.
Before installation and operation of the gate opener, please read all instructions carefully.
Our company reverses the right to change the instruction without prior notice.
6.2 Troubleshooting
The gate cannot be
properly opened or
closed, and indicator
light does not light.
1. The power is off.
2. Battery power is exhausted.
3. Fuse is burned.
1. Turn on the power switch.
2. Change the battery.
3. Check the fuse of
transformer input port, change
it if burned.
The gate can be opened
but cannot be closed.
1. Infrared protection function is
activated, but not connected with
any infrared protection devices.
2. Wiring problem of infrared
protection devices.
3. Mounting problem of infrared
protection devices.
4. Infrared protection device is
blocked by objects.
5. Sensitivity of meeting obstacles
is too small.
1. Connect with an infrared
protection device or turn off the
infrared protection function.
2. If not connected with any
infrared protection devices,
please make sure to short the
IR and COM ports; If
connected with infrared
protection devices, please
make sure all the wiring is
correct and should be NC.
3. Make sure that the photocell