4. Operation 22
Setting System Alarm
Make SYSTEM ALARM a yellow display, press or the [ENT] key, and the following menu is
displayed.
SYSTEM ALARM
DEPTH LOST OFF
TX ALARM OFF
RX ALARM OFF
BUBBLE ALARM OFF
PRINTER ALARM ON
ޟDEPTH LOSTޠ
٧The alarm operation when sea bottom cannot be detected is selected.
Make DEPTH LOST a yellow display, press or the [ENT] key, and select it from the following, set
content.
Set content OFF/ON
OFF
The sea bottom lost alarm doesn't operate.
ON When sea bottom was not able to be detected 15 times or more, the sea bottom lost
alarm is started.
When sea bottom was not able to be detected 40 times or more with range of
10/20/50m, the sea bottom lost alarm is started.
When sea bottom is detected after the sea bottom lost alarm starts, it is released.
Select the operation by and press the [ENT] key.
ޟTX ALARMޠ
٧When the transmitter becomes abnormal, the alarm operation is selected.
Make TX ALARM a yellow display, press or the [ENT] key, and select it from the following, set
content.
Set content OFF/ON
OFF
The transmission alarm doesn't operate.
ON When abnormality occurs in the transmitter, the transmitter alarm is started.
Select the operation by and press the [ENT] key.
Selecting items move a yellow display with or key.

Table of Contents

Other manuals for JRC JFE-380

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JRC JFE-380 and is the answer not in the manual?

JRC JFE-380 Specifications

General IconGeneral
BrandJRC
ModelJFE-380
CategoryMarine Equipment
LanguageEnglish

Related product manuals