4. Operation  36 
٧Alarm output
$SDALR,hhmmss.ss
,xxx,A,A,c--c*hh<CR><LF>
㩷 (1)  㩷 (2) (3)(4)(5) (6) 
(1) Time of alarm condition change,UTC 
(2) ID number of the alarm source 
㩷㩷351  primary depth alarm 
㩷㩷352  secondary depth alarm 
㩷㩷353  primary depth lost 
㩷㩷354  secondary depth lost 
㩷㩷356  printer paper is not good 
㩷㩷357  printer connection is not good 
㩷㩷360  primary transmit signal is not good 
㩷㩷361    primary receive signal is not good 
㩷㩷362    primary bottom echo signal is not good 
㩷㩷363    secondary transmit signal is not good 
㩷㩷364  secondary receive signal is not good 
㩷㩷365  secondary bottom echo signal is not good 
㩷㩷366    backup data area is not good 
(3) Alarm condition (A = threshold exceeded, V = not exceeded) 
(4) Alarm's acknowledge state (A = acknowledged, V = unacknowledged) 
(5) Alarm's description text 
(6)Checksum (result after each ASCII code of every character between"S" just after"$" and 
㩷㩷"X" just before " * " is EXORed.)