6. Maintenance & Check 47
KEY UNIT
Make KEY UNIT a yellow display, press or the [ENT] key, and the operation unit self test starts.
When the key on the operation panel is pressed, the name of the pressed key is displayed.
However, it returns to the self test menu when the [CLR] key is pressed, and the [CLR] key is judged.
PRINTER TEST
Make PRINTER TEST a yellow display, press or the [ENT] key, and the test pattern is output (print).
This example is printed by NKG-91 option printer.
ALARM TEST
Make ALARM TEST a yellow display, press or the [ENT] key, and select it from the following, set
content.
Set content OFF/DEPTH ALARM/SYSTEM ALARM
When DEPTH ALARM is selected, and the depth alarm is set according to the following procedure, the
test starts.
Menu ALARM" DEPTH ALARM" ALARM CONT" ON" [ENT] key
Menu ALARM" DEPTH ALARM" ALARM SETTING" "A depth value that is deeper
than 1/2 of the scale values is set" [ENT] key.
When the sea bottom lost alarm is set according to the following procedure after SYSTEM ALARM is
selected, the test starts.
Menu ALARM" SYSTEM ALARM" DEPTH LOST" ON" and [ENT] key
Set it to OFF" after ALARM TEST finishes.
When the [CLR] key is pressed, it returns to the self test menu.
Return DEPTH ALARM" and SYSTEM ALARM" to original setting.