– 84 –
Item Setting range Edit unit Initial display
Compensation of unsteady needle
thread tension
Output value of needle thread tension
is wholly offset and compensated.
-30 to 30 1 0
Output time of needle thread tension changed
value
When data related to needle thread tension is
changed, the changed value is output as long as the
set-up time.
0 to 20 1s Without output
: Without output
: Output of set-up time
Function of origin retrieval each time
Origin retrieval is performed after completion of
sewing.
--- --- Without
: Without
: After end of
cycle
: After end
of sewing
Needle up by reverse run Effective/ Ineffective
When U01 Presser lifter maximum position is set to
14.0 mm or more, motion of needle up by reverse run
is automatically performed and the machine stops.
Prohibition of the motion can be set.
--- --- Permitted
: Needle up by reverse run prohibited
: Needle up by reverse run permitted
Knife solenoid lowering time setting
25 to 100 5ms 35
Knife solenoid lifting time setting
5 to 100 5ms 15