– 90 –
Error
code
Description of error
How to
recover
Place of
recovery
E017 EEP-ROM capacity over
Capacity of EEP-ROM is short.
Possible to
re-start after
reset.
Previous
screen
E018 Type of EEP-ROM is different.
When the mounted EEP-ROM is different in type.
Possible to
re-start after
reset.
Previous
screen
E019 File size over
File is too large.
Possible to
re-start after
reset.
Previous
screen
E022 File No. error
DesignatedleisnotinserverorMedia.
Possible to
re-start after
reset.
Previous
screen
E023 Detection of step-out of presser lifting motor
When step-out of motor is detected at the time when
presser lifting motor passes origin sensor or starts
operation.
Possible to
re-start after
reset.
Data input
screen
E024 Pattern data size over
When sewing cannot be performed since total size of
continuous stitching data or size of downloaded data is
too large.
Possible to
re-start after
reset.
Data input
screen
E025 Detection of step-out of needle thread trimmer motor
When step-out of motor is detected at the time when
needle thread trimmer motor passes origin sensor or
starts operation.
Possible to
re-start after
reset.
Data input
screen
E026 Detection of step-out of bobbin thread trimmer motor
When step-out of motor is detected at the time when
bobbin thread trimmer motor passes origin sensor or
starts operation.
Possible to
re-start after
reset.
Data input
screen