Maintenance Guide
9-16
9-18. Z unit
The Z unit is moved from an arbitrary floor to another.
You can select continuous or single operation mode.
Starting Z unit
Select 17. Z Unitin the menu.
Use and buttons to increment or decrement the floor number and set the destination
floor. Press the ENTER button.
Fig. 9-18-1 Setting of destination floor
Selecting operation mode
Use and buttons to move the cursor and select continuous or single operation mode.
Press the ENTER button.
Fig. 9-18-2 Selection of operation
Starting operation
Press the ENTER button to start the operation.
Fig. 9-18-3 Operation in progress
Finishing operation
In the single operation mode, the display returns to the operation selection screen when
the operation is completed.
In the continuous operation mode, press the CANCEL button to return to the operation
selection screen .
Another pressing the CANCEL button changes the display to the and then to the menu
screen.The system returns to the menu screen with the Z unit position being kept.
17. Z Unit
Floor 1 → 2
17. Z Unit
Cont One
17.Z Unit
Moving・・・