70
Sensor: Curr
Unit: mAh
Persistent: When selected, this value will remain during power down and resume
during power up.
Logs: If checked, will be logged to the SD card. Please note that the record must
still be started by the Special Function.
Variometer settings:
The vario sensor adds the Vspd and Alt parameters to the sensor list.
Source: To enable vario, set "VSpd" as the source on the main telemetry page
under the "Variometer" heading.
Range: Sets the maximum expected sink rate (-17 to -3, default -10m/s) and the
maximum rate of climb (3 to 17 and defaults to 10m/s) for the sounds generated by
the Vario custom function.
Center: Sets the sink/climb rate limit for the center "dead zone" (-2.1 to 0.5,
default -0.5 and -0.5 to 2.0, default is 0.5m/s). Replace "Tone" with "Silent" to turn off
the tone in the center range.
If you want to use the switch to open and close vario as shown below.