Table 10: CTP2008 Platform Specifications (continued)
SpecificationCategory
50–60 HzAC line frequency
2.0Nominal current (115V amps)
200 WPower
3 ft. (90 cm) behind device or rack.
Do not block air vents on the front or back of the device.
Space Requirements
Air intake occurs from the front of the device.
Air is exhausted out the back of the device.
Airflow
•
AS/NZS 60950:2000 Safety of Information Technology Equipment
•
CAN/CSA-C22.2, No. 60950-1–03, First Edition, Information Technology
Equipment - Safety - Part 1: General Requirements
•
EN60825-1, Safety of Laser Products - Part 1: Equipment Class, Requirements,
and User's Guide (2001)
•
IEC 60950-1(2001-10) Ed. 1.0 Information Technology Equipment - Safety -
Part 1: General Requirements
•
Low Voltage Directive (2006/95/EC)
•
UL 60950-1, First Edition, Information Technology Equipment - Safety - Part 1:
General Requirements
Safety Agency Certification
•
AS/NZS CISPR 22:2004
•
EMC Directive (89/336/EEC)
•
EN 300 132–2 (Narrowband and Wideband)
•
EN55022 Class A (CISPR-22 Class A)
•
EN55024, Annex C for WAN Equipment Performance Criteria A, B, and C
•
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6
•
ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic
Compatibility (EMC) requirements
•
IECS-03 Issue 3 Class A
•
FCC Part 15 Class A
•
VCCI (Voluntary Control Council for Interference by Information Technology
Equipment)
Electromagnetic Emissions Agency
Certification