Table 20: AC Power Cord Specifications (continued)
Model NumberCountry
CBL-JX-PWR-UKUnited Kingdom
WARNING: The AC power cord for the services gateway is intended for use
with the services gateway only and not for any other use.
Related
Documentation
SRX240 Services Gateway Site Electrical Wiring Guidelines on page 35
SRX240 Services Gateway Grounding Specifications on page 59
SRX240 Services Gateway Power Supply on page 25
SRX240 Services Gateway DC Power Specifications and Requirements on page 38
SRX240 Services Gateway DC Power Specifications and Requirements
This topic includes the following sections:
DC Power System Electrical Specifications on page 38
DC Power Cable Specifications on page 38
DC Power System Electrical Specifications
Table 21 on page 38 lists the DC power system electrical specifications.
Table 21: DC Power Supply Specifications for the SRX240 Services
Gateway
SpecificationPower Requirement
Operating range: –40.5 to 72 VDCDC input voltage
5A @ -48 VDCDC system current rating
DC Power Cable Specifications
Table 22 on page 38 summarizes the specifications for the power cables, which you must
supply.
Table 22: DC Power Supply Cable Specifications for the SRX240 Services
Gateway
SpecificationCable Type
Four 12-14 AWG (3.31 to 2.08 mm2), minimum 60°C wire, or as
permitted by the local code.