1-17
M3
0 : Active
1 : Inactive
M2
0 : Active
1 : Inactive
M1
0 : Increase
1 : Decrease
DATA
0 – 31
MODE
R±(R-G)
R±(R-B)
G+(G-R)
G–(G-R)
G+(G-B)
G–(G-B)
B+(B-G)
B–(B-G)
B±(B-R)
M3
M3
M2
M2
M2
M2
M3
M3
M3
M3
M3
M2
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
0 or 1
Active Area
Graph display
(6) Set DIP switch S901-6 on the ROM board to OFF. The color-
matrix setting menu is canceled and the normal screen ap-
pears again.
NOTE
If the [STATUS] switch is pressed during the value of some
adjustment item is blinking, all of the data being set is reset
to the default values.
1.12.2 Details of Setting Items
As described above, the color matrix setting consists of varying
12 items using 9 parameters. The following table shows a com-
parison of the setting items.
(Example)
This diagram represents the display area of the vectorscope.
NOTE
The model diagrams in the table may be interpreted as fol-
lows.
Table 1-12-1
Inactive area:
Represents a vector area
that is not affected by a
currently selected setting
item.
M1 = 0: Increasing trend
M1 = 1: Decreasing trend
Color signal increase/decrease trend:
The increase or decrease trend can be
selected with M1.
Active area:
Represents the vector area that is affected
by a currently selected setting item.
(The area can be selected with M3 or M2
depending on the item.)
NOTE
The settings are stored and reflected every time a value in
an item is changed. The setting values marked “X” do not
need to be changed.