1-23
1.15 BATTERY POWER DETECTION METHODS
The battery voltage is detected to display the remaining power
on the LCD. Since the detection voltage is variable depending
on the 12 V/13.2 V/14.4 V battery types, correct settings should
be made with the setup menu.
Detection voltage and remaining battery display
12V
12.6V
12.0V 12.5V
11.8V 11.9V
11.6V 11.7V
11.3V 11.5V
11.2V
11.0V 11.1V
10.6V 10.9V
10.5V
EFBATT
EFBATT
EFBATT
EFBATT
EFBATT
EFBATT
EFBATT
EFBATT
EFBATT
13.2V
3.9V
13.2V 13.8V
13.0V 13.1V
12.8V 12.9V
12.4V 12.7V
12.3V
11.6V 12.2V
10.6V 11.5V
10.5V
14.4V
15.1V
14.4V 15.0V
14.2V 14.3V
13.9V 14.1V
13.6V 13.8V
13.4V 13.5V
12.6V 13.3V
10.6V 12.5V
10.5V
Display
Battery Type
(F off)
(F off)
(F off)
(F off)
(F off)
(F off, BATT blinking)
(Segment blinking)
(F off, BATT blinking)
(Segment blinking)
(F off, BATT blinking)
(Segments off)
1.16 WARNING CODES
If a problem occurs during operation, the unit diagnoses the
cause by itself, provides a warning through the warning LED
and buzzer, and displays the diagnosis results in the counter
display.
[LCD counter]
Error display appears. (∗∗∗∗ is the error code.)
ERR-∗∗∗∗
[Warning LED]
The red LED blinks (at about 4 Hz).
[Buzzer]
Generates a continuous tone. However, the tone is intermittent
(at about 4 Hz) in case of dew alarm.
0201 Condensation
VCR operation
In save mode:
· If a cassette is loaded, enters the AUTO OFF mode.
· If a cassette is not loaded, the warning LED lights
and the SAVE mode is maintained.
In other modes:
· If a cassette is loaded, the AUTO OFF mode is ini-
tiated.
· If a cassette is not loaded, the warning LED lights
and the drum rotates. An operation is accepted af-
ter any condensation has evaporated.
Cause : Condensation of moisture.
Detection method : Check the voltage at the pin 124 of
IC401.
DEW ON : 2.4 V or more
DEW OFF : 1.8 V or less
0601 WRONG CASSETTE TYPE
VCR operation : The AUTO OFF mode is initiated.
Cause : A wrong type of cassette for the
computer is inserted.
Detection method : An error in the cassette type is de-
tected (at pins 117, 118 and 119 of
IC401) after the insertion is com-
pleted.
3200 LOADING INCOMPLETE
VCR operation : The AUTO OFF mode is initiated.
Cause : Malfunction of the loading motor,
rotary encoder or mechanism.
Detection method : The rotary encoder output is
checked (at pins 44, 45 and 46 of
IC401) and an error is detected
when loading has not completed in
4 seconds.

Other manuals for JVC GY-DV500U