3-11
No. Item
Measuring
instruments &
Input signals
Mode
Measuring point
(*)
Adjustment parts
(-)
Adjustment level
(+)
Adjustment procedure
2
ABL adjust-
ment
• Oscilloscope
(H-rate, 10:1)
or WFM
• Gray scale chart
(precise
scanned size)
Adjustment
menu 5/6
* TEST OUT
(75 Ø terminated)
- SHUTTER/MENU
dial
+ Gray scale chart
window black level:
(1) Rotate the SHUTTER/MENU dial to select
MENU 5/6: ABL.
(2) Push the SHUTTER/MENU dial so that the ad-
justment value blinks then rotate it to adjust to
the specified level.
(3) Push the SHUTTER/MENU dial to store the
adjustment data in memory.
FLARE B : O
FLARE R : O
ABL ADJUST :O
DSP data
<Bch> <Gch> <Rch>
32 32 32
C– AMERA ADJUST MENU– 5 / 6
1
IRIS LEVEL
adjustment
• Oscilloscope
(H-rate, 10:1)
or WFM
• Monitor TV
• Gray scale chart
(precise
scanned size)
Adjustment
menu 6/6
* TEST OUT
(75 Ø terminated)
- SHUTTER/MENU
dial
+
(1) Rotate the SHUTTER/MENU dial to select
MENU 6/6: IRIS LEVEL.
(2) Push the SHUTTER/MENU dial so that the ad-
justment value blinks then rotate it to adjust to
the specified level.
(3) Push the SHUTTER/MENU dial to store the
adjustment data in memory.
I R I S LEVEL : O
C– AMERA ADJ UST MENU– 6 / 6
3.5.6 Iris Level Adjustment
NTSC 0.714 Vp-p
PAL 0.7 Vp-p
NTSC 0.714 ± 0.03 Vp-p
PAL 0.7 ± 0.03 Vp-p
NTSC 110 +5/–0 mVp-p
PAL 55 +5/–0 mVp-p
3-10