3-22
No. Item
Measuring
instruments &
Input signals
Mode
Measuring point
(*)
Adjustment parts
(-)
Adjustment level
(+)
Adjustment procedure
1
Fs PLL (48k)
adjustment
No signal
Frequency
counter
EE *
TP FS PLL
(connector cable)
-
62h
+ 12.288 ± 0.020 MHz
(1) Click [Fs PLL (48k)].
(2) Click the [OK] button.
(3) Adjust New value (address 62h) so that
the frequency level becomes the adjustment
level.
(4) After adjustment, click the v marking and
set the power button of the set to OFF.
3.7.10 Audio Circuit Adjustment
2
Fs PLL (44.1k)
adjustment
No signal
Frequency
counter
EE *
TP FS PLL
(connector cable)
-
FCh
+
11.2896 ± 0.110 MHz
(1) Click [Fs PLL (44.1k)].
(2) Click the [OK] button.
(3) Adjust New value (address FCh) so that
the frequency level becomes the adjustment
level.
(4) After adjustment, click the v marking and
set the power button of the set to OFF.
3
Fs PLL (38k)
adjustment
No signal
Frequency
counter
EE *
TP FS PLL
(connector cable)
-
FDh
+ 8.192 ± 0.080 MHz
(1) Click [Fs PLL (38k)].
(2) Click the [OK] button.
(3) Adjust New value (address FDh) so that
the frequency level becomes the adjustment
level.
(4) After adjustment, click the v marking and
set the power button of the set to OFF.