KAESER ASK Series - Heat Recovery; Tab. 30 Supply Details 230 V; 3; 60 Hz; Tab. 31 Supply Details 380 V; 3; 60 Hz; Tab. 32 Supply Details 440 V; 3; 60 Hz

KAESER ASK Series
138 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASK 28 ASK 34 ASK 40
Supply cable [mm
2
]
4x16 4x25 4x35
Current drawn [A] 58 71 80
Tab. 30 Supply details 230V / 3 / 60Hz
Rated voltage: 380V / 3 / 60Hz
ASK 28 ASK 34 ASK 40
Backup fuse [A] 40 50 63
Supply cable [mm
2
]
4x10 4x10 4x16
Current drawn [A] 35 43 49
Tab. 31 Supply details 380V / 3 / 60Hz
Rated voltage: 440V / 3 / 60Hz
ASK 28 ASK 34 ASK 40
Backup fuse [A] 40 50 50
Supply cable [mm
2
]
4x10 4x10 4x10
Current drawn [A] 30 36 42
Tab. 32 Supply details 440V / 3 / 60Hz
Rated voltage: 460V / 3 / 60Hz
ASK 28 ASK 34 ASK 40
Backup fuse [A] 40 40 50
Supply cable [mm
2
]
4x10 4x10 4x10
Current drawn [A] 29 35 40
Tab. 33 Supply details 460V / 3 / 60Hz
2.15 Option W2/W3
Heat recovery
There are typical layout examples. Conditions for each individual installation could vary from these
guidelines.
The reasons may be (examples):
Fluctuating condensate flow
Working pressure
Inlet conditions
Ambient conditions
Machine settings
Water is generally the heat-receiving medium. The water must meet the quality specified below in
order not to damage the heat exchanger.
2 Technical Specifications
2.15 Heat recovery
14
Operating Manual Screw Compressor
ASK 901824 12 E