5 Installation and Operating Conditions
5.1 Ensuring safety
The conditions in which the machine is installed and operated have a decisive effect on safety.
Warning instructions are located before a potentially dangerous task.
Disregard of warning instructions can cause serious injuries!
Complying with safety notes
Disregard of safety notes can cause unforeseeable dangers!
Strictly forbid fire, open flame and smoking.
If welding is carried out on or near the machine, take adequate measures to prevent sparks or
heat from igniting oil vapours or parts of the machine.
Do not store inflammable material in the vicinity of the machine.
The machine is not explosion-proof!
Do not operate in areas in which specific requirements with regard to explosion protection are
in force.
For instance, the requirements of ATEX directive 2014/34/EC "Equipment and Protective Sys‐
tems intended for use in Potentially Explosive Atmospheres".
Ensure sufficient and suitable lighting such that the display can be read and work carried out
comfortably and safely.
Keep suitable fire extinguishing agents ready for use.
Ensure that required ambient conditions are maintained.
Required ambient conditions may be:
Maintain ambient temperature and humidity
Ensure the appropriate composition of the air within the machine room:
clean with no damaging contaminants (e.g., dust, fibres, fine sand)
free of explosive or chemically unstable gases or vapours
free of acid/alkaline forming substances, particularly ammonia, chlorine or hydrogen sulfide.
5.2 Installation conditions
5.2.1 Determining location and clearances
The machine is intended for installation in an appropriate machine room. Information on distances
from walls and ventilation of the machine room is provided below.
The clearances given are recommended and ensure unhindered access to all machine parts.
Please consult KAESER if they cannot be adhered to.
Precondition The floor must be level, firm and capable of bearing the mass of the machine.
5 Installation and Operating Conditions
5.1 Ensuring safety
38
Operating Manual Screw Compressor
ASK 901824 12 E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASK Series and is the answer not in the manual?

KAESER ASK Series Specifications

General IconGeneral
ModelASK Series
TypeRotary Screw Compressor
Motor TypeIE3 Premium Efficiency
CoolingAir / Water
DriveDirect
Control SystemSIGMA CONTROL
WeightVaries by model