Result The
Voltage applied to controller
LED extinguishes. The machine is switched off and disconnected
from the mains supply.
In rare cases, you may want to shut down the machine immediately and cannot wait until the
automatic shut-down process is finished.
Press «OFF» once again.
8.2 Switching off in an emergency and switching on again
The EMERGENCY STOP control device is located below the control panel.
Fig. 16 Switching off in an emergency
9 EMERGENCY STOP control device
Switching off
Press the EMERGENCY STOP control device.
Result The EMERGENCY STOP control device remains latched after actuation.
The compressor's pressure system is vented and the machine is prevented from automatically re-
starting.
Switching on
Precondition The fault has been rectified
1. Turn the EMERGENCY STOP control device in the direction of the arrow to unlatch it.
2. Acknowledge any existing alarm messages.
Result The machine can now be started again.
8.3 Using the remote control for switching on and off
Precondition A link to the remote control centre exists.
8 Operation
8.2 Switching off in an emergency and switching on again
901824 12 E
Operating Manual Screw Compressor
ASK
53

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASK Series and is the answer not in the manual?

KAESER ASK Series Specifications

General IconGeneral
ModelASK Series
TypeRotary Screw Compressor
Motor TypeIE3 Premium Efficiency
CoolingAir / Water
DriveDirect
Control SystemSIGMA CONTROL
WeightVaries by model