4.4 Operating modes and control modes
4.4.1 Machine operating modes
STOP
The machine is connected to the power supply.
The
voltage applied to controller
LED lights green.
The machine is switched off. The
on
LED is extinguished.
READY
The machine has been activated with «ON»:
The
on
LED lights green.
The drive motor is stopped.
The inlet valve is closed.
The minimum pressure/check valve isolates the oil separator tank from the air system.
The venting valve is open.
The compressor motor starts as soon as system pressure is lower than the set point pressure (cut-
off pressure).
In addition, timing and/or remote control may affect the start of the motor.
LOAD
The compressor motor runs under load.
The inlet valve is open.
The compressor block delivers compressed air to the system.
IDLE
The compressor motor runs unloaded with low power consumption.
The inlet valve is closed.
The minimum pressure/check valve isolates the oil separator tank from the air system.
The venting valve is open.
A small volume of air circulates through the bypass bore in the inlet valve, through the compressor
block and back to the inlet valve via the venting line.
4.4.2 Control modes
Using the selected control mode, the controller switches the machine between its various opera‐
tional states in order to maintain the gauge working pressure between the set minimum and maxi‐
mum values, regardless of the drawn compressed air volume. The control mode also rules the de‐
gree of energy efficiency of the machine.
The shortest possible times for the various parameters is preset by the factory to ensure that the
compressor motor earlier and more frequently is at standstill. If you want to change these parame‐
ters, select the shortest possible times in order for the machine working energy-efficiently.
The machine-dependant venting time between the LOAD and READY operating modes ensures
load changes at minimum material stresses.
4 Design and Function
4.4 Operating modes and control modes
34
Operating Manual Screw Compressor
ASK 901824 12 E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER ASK Series and is the answer not in the manual?

KAESER ASK Series Specifications

General IconGeneral
ModelASK Series
TypeRotary Screw Compressor
Motor TypeIE3 Premium Efficiency
CoolingAir / Water
DriveDirect
Control SystemSIGMA CONTROL
WeightVaries by model

Related product manuals