Option Option code Available?
Heat recovery ΔT=45 K W2
Heat recovery ΔT=55 K W3
Tab. 3 Options
2.3 Weight
The weight given is the maximum. Actual weights of individual machines are dependent on equipment
fitted.
BSD 40 BSD 50 BSD 60
Weight [lb] 2270 2350 2540
Tab. 4 Machine weight
2.4 Temperature
BSD 40 BSD 50 BSD 60
Minimum cut-in tempera‐
ture [°F]
40 40 40
Typical airend discharge
temperature during opera‐
tion [°F]
167–200 167–200 167–200
Maximum. airend dis‐
charge temp. (automatic
shut-down) [°F]
230 230 230
Tab. 5 Temperature
2.5 Ambient Conditions
BSD 40 BSD 50 BSD 60
Maximum elevation [ft.] 3000 3000 3000
Permissible ambient tem‐
perature [°F]
40–115 40–115 40–115
Cooling air temperature
[°F]
40–115 40–115 40–115
Inlet air temperature [°F] 40–115 40–115 40–115
Maximum relative humidi‐
ty of inlet air
see figure 1 see figure 1 see figure 1
* Higher elevation permissible only after consultation with the manufacturer
Tab. 6 Ambient Conditions
2 Technical Data
2.3 Weight
4
Service Manual Screw Compressor
BSD 9_5708 08 USE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER BSD 50 and is the answer not in the manual?

KAESER BSD 50 Specifications

General IconGeneral
ModelBSD 50
CategoryRotary Screw Compressor
Motor Power30 kW
Noise Level69 dB(A)
Drive TypeDirect

Related product manuals