8. Attach the air pipe to the cover 14 with a new, self-locking nut.
9. Replace and tighten all fittings.
➤ Dispose of parts and materials contaminated with oil in accordance with environmental
protection regulations.
Start the machine and carry out a test run
1. Close all access doors; replace and secure all removable panels.
2. Open the user's shut-off valve between the machine and the compressed air system.
3. Switch on the power supply and reset the maintenance interval counter.
4. Stop the machine after 10 minutes and visually check for leaks.
10 Maintenance
10.18 Changing the Oil Separator Cartridge
86
Service Manual Screw Compressor
BSD 9_5708 08 USE