Feature Value
PTC testing current [A]
(according to EN 50342)
480
Tab. 32 Battery
Further information Depending on machine equipment, a higher capacity battery may be required. See chapter 2.7.2
for low temperature equipment.
2.7 Options
2.7.1 Option ea
Tool lubricator
Name Temperature range [°C] Fluid volume [l]
Special road breaker lubricant −25 – 50 2,5
Tab. 33 Road breaker lubricant recommendation
2.7.2 Option ba, bb
Low temperature equipment
2.7.2.1 Ambient conditions
Positioning Limit value
Maximum altitude AMSL* [m] 1000
Minimum ambient temperature [°C] −25
Maximum ambient temperature [°C] 50
* Higher altitudes are permissible only after consultation with the manufacturer.
Tab. 34 Ambient conditions
2.7.2.2 Option ba
Air lines frost protection
Antifreeze Fluid volume [l]
Wabcothyl 0,3
Tab. 35 Antifreeze recommendation
2.7.2.3 Option bb
Coolant pre-heating
Coolant pre-heater Value
Model DEFA A411120
Voltage [V] 230
Power [W] 600
Tab. 36 Coolant pre-heater
2 Technical Specification
2.7 Options
12
Service Manual Screw Compressor
M43 No.: 9_9432 02 E