9.3.3 Pressure relief valve blowing off
Possible cause Remedy Where can I get help?
Specialised
workshop
KAESER Ser‐
vice
Oil separator cartridge heavily
clogged.
Change, see chapter 10.4.5.
Inlet valve not closing. Check the controller, the control
air line and the inlet valve and
replace if necessary.
X
Pressure relief valve maladjus‐
ted and/or leaking.
Adjust or have replaced if nec‐
essary.
X
Tab. 51 Fault: pressure relief valve blowing off
9.3.4 Machine overheating
Possible cause Remedy Where can I get help?
Specialised
workshop
KAESER Ser‐
vice
Defective cooling fan. Have the blades or the complete
fan wheel replaced.
X
Oil cooler clogged. Clean surface, see chap‐
ter 10.4.8.
Defective working element in the
combination valve.
Have repaired or replaced if
necessary.
X
Working pressure too high (pro‐
portional controller maladjus‐
ted).
Reset to the permissible value
or have replaced.
X
Oil separator cartridge heavily
clogged.
Measure the pressure differen‐
tial and change the cartridge if
greater than 1 bar (see chap‐
ter 10.4.5).
X
Compressor oil filter clogged. Change, see chapter 10.4.4.
Compressor oil level too low. Top up (see chapter 10.4.2).
Oil pipes leaking. Seal leaks or have pipes
changed.
X X
Engine cooling system or cool‐
ing fan defective.
Have repaired. X X
Ambient temperature too high. See installation conditions in
chapter 5.2.
Tab. 52 Fault: machine overheating