Dene CP-Parameters
© KEB, 2008-02 COMBIVERT R6-S Page 3.9 - 5
3
10
Display standardization
Bit 10 .. 12 determines how to display the parameter value. With parameters ud.18 ... 21 itispossibletodene
up to seven different user standardizations (below in this chapter).
Bit
12 11 10 Value Function
0 0 0 0 Use standardization of the parameter
0 0 1 1024 Display standardization of parameters ud.18...21 of set 1
0 1 0 2048 Display standardization of parameters ud.18...21 of set 2
... ...
1 1 1 7168 Display standardization of parameters ud.18...21 of set 7