Dene CP-Parameters
© KEB, 2008-02 COMBIVERT R6-S Page 3.9 - 9
3
10
Table 2 calculation mode (bit 6...7)
Value Function
0 (selected parameter + ud.20) x
ud.19
———
ud.18
= CP.xx
64
ud.19
———————————————————
(selected parameter + ud.20) x ud.18
= CP.xx
- free
The "non-standardized value" is used for the „selected parameter“ !
non-standardized value = standardized value / resolution
Table 3 display (bit 8...11)
Value Display
0 0 decimal places
256 1 decimal place
512 2 decimal places
768 3 decimal places
1024 4 decimal places
1280 variable decimal places
1536 Hexadecimal
- free