Seite 3.4 - 16 COMBIVERT R6-S © KEB, 2008-02
Digital in- and outputs
Picture 3.4.18 Linking of the conditions in logic step 1
&
&
&
>
>
>
0
1
0
1
0
1
Bit 0
Bit 1
Bit 7
O1
O2
OD
do.24
1
1
1
8
8
8
do.16
do.17
do.23
Flag 0
Flag 1
Flag 7
3.4.19 Invert of ags (do.25...do.32)
Picture3.4.19Invertandselectionofags
do.00
do.01
do.02
do.03
do.04
do.05
do.06
do.07
1
1
1
1
1
1
1
1
8
1
2
4
8
16
32
64
128
1
2
4
8
16
32
64
128
do.25...32 do.33...40
&
&
&
>
>
>
0
1
0
1
0
1
Bit 0
Bit 1
Bit 7
O1
O2
OD
do.41
1
1
1
With parameters do.25...do.32 each of the 8 ags(Bit0...7)oflogicstep1canbeinvertedseparately.
Anyagcanbeusedasnon-agbythisfunction.Theparameterisbit-coded.Thevaluefortheagtobein-
verted must be entered in do.25...do.32 according to picture3.4.19.Ifseveralagsshallbeinverted,thesum
must be formed.
3.4.20 Selection of ags (do.33...do.40)
Aselectionofagsfromtherstlogicstepcanbemetinthesecondlogicstep.Theselectionisdoneseparately
foreachoutput,wherebyitcanbeselectedbetweennoanduptoall8ags.Thevaluefortheselectedags
must be entered in do.33....do.40accordingtopicture3.4.19.Ifseveralagsshallbeselected,thesummust
be formed.

Table of Contents

Other manuals for KEB combivert R6-S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB combivert R6-S and is the answer not in the manual?

KEB combivert R6-S Specifications

General IconGeneral
BrandKEB
Modelcombivert R6-S
CategoryPower Supply
LanguageEnglish

Related product manuals