Page3.5 - 4 COMBIVERT R6-S © KEB, 2008-02
Regenerative adjustments
3.5.3 Activate regeneration
The activation of the regeneration is dependent on the reference value of the DC voltage (ru.18) and the re-
generation level cS.02.
The regeneration unit starts to modulate if the DC voltage exceedsthespeciedvalueincS.02,whichis per-
cental related to the reference voltage.
Parameter Addr. R PG E Min.
value
Max.
value
Res. [?] Default
cS.02 Regeneration level 0F02h rw - - 100 120 1 % 103
3.5.4 Deactivate regeneration
If the active power exceeds the level specied in cS.06 the modulation is switched off after puls off delay
(cS.05).
Parameter Addr. R PG E Min.
value
Max.
value
Res. [?] Default
cS.05 Puls off delay 0F05h rw - - 0 32000 1 ms 200
Parameter Addr. R PG E Min.
value
Max.
value
Res. [?] Default
cS.06 Puls off level 0F06h rw - - -10000 0 1 kW -0,8