Safety
Operation Manual Supply Unit SO CM-P BG1+2
ID no.: 1400.201B.5-00 Date: 02/2020
Safety
y The emergency stop function (as per EN 60204) shuts down the supply of pow-
er to a machine, which results in the drives coasting down in an uncontrolled
manner. To avert hazards, check whether it is appropriate:
To keep individual drives in operation
To initiate specic safety procedures
To incorporate a Safe Torque Off function (Safe Torque Off: movement stop
by "switching off the electrical supply" or STO)
2.7 Relevant laws, standards and directives
applied
For information on the laws, standards and directives applied by KEBA, refer to the
declaration of conformity.
Note:
Depending on the specic application for the devices, other laws, standards
and directives with provisions on "safety" may apply. If necessary, contact the
machine or system manufacturer.
2.5 Misuse
Our devices are:
y Not intended for installation in vehicles. Deployment of the device in mobile
equipment is classed as non-standard ambient conditions and is permissible
only by special agreement.
y Not intended for installation in environments with harmful oils, acids, gases,
vapours, dusts, radiation etc.
y Not approved for usage in special applications (e.g. in potentially explosive
atmospheres or areas in which there is a risk of re).
y Not approved for usage outside a switch cabinet.
y Not approved for the generation of high-frequency onboard
networks for which the devices are not designed.
Note:
The use of devices in warehouse storage and retrieval systems that are
operated inside and outside the rack aisle on rails is allowed provided
the vibration does not exceed the maximum standard values 3M1 as per
DINEN60721-3-3.
2.6 Responsibility
Electronic devices are not fail-safe. The installer and/or operator of a complete machine
or system is responsible:
y For ensuring the drive is rendered safe if the device fails
y For ensuring the safety of personnel and machinery
y For ensuring the complete machine is in correct working order
y For the risk assessment on the complete machine or system according to
DIN EN 12100:2011 (formerly DIN EN 14121:2007) and EN ISO 13849-1 (for-
merly DIN EN 954-1)
In EN60204-1:2006 "Safety of machinery", pay attention to:
y The topic of "Electrical equipment of machines". The safety requirements on
electrical machines dened there are intended to protect personnel and machin-
ery or systems.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba ServoOne CM-P BG1 and is the answer not in the manual?

Keba ServoOne CM-P BG1 Specifications

General IconGeneral
BrandKeba
ModelServoOne CM-P BG1
CategoryPower Supply
LanguageEnglish

Related product manuals