Operation Manual Supply Unit SO CM-P BG1+2
ID no.: 1400.201B.5-00 Date: 02/2020
A.5 Certication
A.5.1 CE certication
The ServoOne CM-P supply unit conforms to the requirements of the Low Voltage
Directive 2006/95/EC and the product standard EN61800-5-1.
The ServoOne CM-P supply unit conforms to the requirements for installation in a
machine or plant under the terms of the Machinery Directive 2006/42/EC.
The supply unit is accordingly CE marked. The CE marking on the rating plate indicates
conformity with the above directives.
A.5.2 UL certication
You will nd information on the certication according to UL61800-5-1 for the
ServoOne CM-P supply unit in the document "UL-Certication" ID no.: 0927.21B.x.
A.5.3 Load on the mains due to harmonics
(EN 61000-3-2:2006)
The devices in the ServoOne CM system are "professional equipment" in the context of
EN61000 such that with a nominal connected load ≤1kW (or 16A per mains phase)
they fall within the scope of the standard. On the direct connection of the supply unit
≤1kW to the public low-voltage network, either measures to conform to the standard
are to be taken or the responsible utility must grant approval for connection. If you
should use our drive units as a component in your machine / system, then the scope of
the standard is to be checked for the complete machine / system.
A.4 Power reduction at T
unom
≥ 40°C
If the multi-axis system is operated outside the specied maximum ambient temperature
(T
unom
), the output power of the supply unit must be reduced as a function of the higher
ambient temperature; this reduction will have an effect on the current in the DC link
connections. This so-called temperature derating is used to protect parts in the device
against overheating.
Device
Operation without
derating up to T
unom
Operation with
derating up to T
umax
Derating for
T
unom
< T
u
< T
umax
SOCM-P.0010 / SOCM-P.0110
SOCM-P.0022 / SOCM-P.0122
40 °C 55 °C
Reduction of the output
power
by 3.0 % per 1 °C
Table E.8 Power reduction at TUNOM ≥ 40°C
NOTE:
The derating is to be applied both to the rated currents and to the overload
currents.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keba ServoOne CM-P BG1 and is the answer not in the manual?

Keba ServoOne CM-P BG1 Specifications

General IconGeneral
BrandKeba
ModelServoOne CM-P BG1
CategoryPower Supply
LanguageEnglish

Related product manuals