SCPI Conformance Information
F-2
:STATus
:OPERation
[:EVENt]?
:CONDition?
:PTRansition <n>
:PTRansition?
:NTRansition <n>
:NTRansition?
:ENABle <n>
:ENABle?
:ARM
[:EVENt]?
:CONDition?
:PTRansition <n>
:PTRansition?
:NTRansition <n>
:NTRansition?
:ENABle <n>
:ENABle?
:SEQuence
[:EVENt]?
:CONDition?
:PTRansition <n>
:PTRansition?
:NTRansition <n>
:NTRansition?
:ENABle <n>
:ENABle?
:TRIGger
[:EVENt]?
:CONDition?
:PTRansition <n>
:PTRansition?
:NTRansition <n>
:NTRansition?
:ENABle <n>
:ENABle?
:PRESet
:QUEue
[:NEXT]?
:ENABle <list>
Path to control operation event registers:
Read the status register.
Read the condition register.
Program the positive transition register (0 to 1122).
Read the positive transition register.
Program the negative transition register (0 to 1122).
Read the negative transition register.
Program the enable register (0 to 1122).
Read the enable register.
Path to control arm event registers:
Read the status register.
Read the condition register.
Program the positive transition register (0 or 2).
Read the positive transition register.
Program the negative transition register (0 or 2).
Read the negative transition register.
Program the enable register (0 or 2).
Read the enable register.
Path to control the sequence event registers:
Read the status register.
Read the condition register.
Program the positive transition register (0 to 6).
Read the positive transition register.
Program the negative transition register (0 to 6).
Read the negative transition register.
Program the enable register (0 to 6).
Read the enable register.
Path to control trigger event registers:
Read the status register.
Read the condition register.
Program the positive transition register (0 or 2).
Read the positive transition register.
Program the negative transition register (0 or 2).
Read the negative transition register.
Program the enable register (0 or 2).
Read the enable register.
Return status registers to default states.
Path to access error queue:
Request most recent error message.
Specify error and status messages for queue.
Table F-1 (continued)
Syntax of SCPI confirmed commands implemented by Model 7001
Command Description
Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Table of Contents

Other manuals for Keithley 7001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 7001 and is the answer not in the manual?

Keithley 7001 Specifications

General IconGeneral
BrandKeithley
Model7001
CategorySwitch
LanguageEnglish

Related product manuals