STATus:QUEStionable<1|2>[:EVENt]?
Queries the event register for the Questionable Status group. This is a read-only register, which
stores (latches) all events that are passed by the Operation NTR and/or PTR filter. Reading the
Questionable Status Event register clears it.
Parameter Typical Return
(none) <bit value>
Read questionable status event register #1: STAT:QUES1?
l The value returned is the binary-weighted sum of all bits set in the register. For example, to
enable bit 2 (decimal value = 4), bit 4 (decimal value = 16), the corresponding decimal value would
be 20 (4 + 16).
l *RST has no effect on this register.
STATus:QUEStionable<1|2>:CONDition?
Queries the condition register for the Questionable Status group. This is a read-only register, which
holds the live (unlatched) operational status of the instrument. Reading the Questionable Status
Condition register does not clear it.
Parameter Typical Return
(none) <bitvalue>
Read questionable status condition register #1: STAT:QUES1:COND?
l The value returned is the binary-weighted sum of all bits set in the register. For example, to
enable bit 2 (decimal value = 4), bit 4 (decimal value = 16), the corresponding decimal value would
be 20 (4 + 16).
l The condition register bits reflect the current condition. If a condition goes away, the cor-
responding bit is cleared.
l *RST clears this register, other than those bits where the condition still exists after *RST.
STATus:QUEStionable<1|2>:ENABle <value>
STATus:QUEStionable<1|2>:ENABle?
Sets the value of the enable register for the Questionable Status group. The enable register is a mask
for enabling specific bits from the Operation Event register to set the QUES (questionable summary) bit
of the Status Byte register. STATus:PRESet clears all bits in the enable register.
Parameter Typical Return
A decimal value corresponding to the binary-
weighted sum of the register's bits.
<bitvalue>
Enable bit2 and 4 in the questionable enable register #1: STAT:QUES1:ENAB 24
6 SCPI Programming Reference
267 Keysight N6900/N7900 Series Operating and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N6972A with Option 301 and is the answer not in the manual?

Keysight Technologies N6972A with Option 301 Specifications

General IconGeneral
BrandKeysight Technologies
ModelN6972A with Option 301
CategoryPower Supply
LanguageEnglish

Related product manuals