120 Chapter 7
Technical Characteristics
• 2.4V nominal when terminated into a 50 ohm load
*Trigger Out has additional latency.
LXI Trigger Bus
• All physical and electrical characteristics conform to LXI Standard Revision 1.1
Module synchronization
• Hardware supports synchronization of multiple AWGs with future software
enhancements.
• Sync clock output level: 800 mVp-p 50 ohm output impedance, AC coupled
• Sync clock input level: 100 mVp-p into 50 ohms AC coupled
Analog output
• Output connector: SMA female
• Output impedance: ~50 ohms
Analog output levels
The following output levels are specified into 50 ohms
• Uncorrected passband flatness: +/- 1 dB DC - 200 MHz;
• Passive Mode Differential: +/- 3.5 dB DC - 500 MHz (with 1.25 GHz clock)
• Uncorrected passband group delay: +/- 500 ps DC - 200 MHz; +/- 1 ns DC - 500
MHz (with 1.25 GHz clock)
• Single-Ended Passive Mode: 0.5Vp-p
• Differential Passive Mode: 1.0Vp-p with ±0.047Vp-p