[:IMMediate]
[:AMPLitude] <value> Sets the output resistance level.
:STATe 0|OFF|1|ON Enables or disables output resistance programming.
:SLEW
[:IMMediate] <value>|INFinity Sets the voltage slew rate.
:MAXimum 0|OFF|1|ON Enables or disables the maximum slew rate override.
STATus
:OPERation
[:EVENt]? Queries the operation event register.
:CONDition? Queries the operation condition register.
:ENABle <value> Sets the operation enable register.
:NTRansiton <value> Sets the Negative transition filter
:PTRansiton <value> Sets the Positive transition filter
:PRESet Presets all Enable, PTR, and NTR registers.
:QUEStionable<1|2>
[:EVENt]? Queries the questionable event register.
:CONDition? Queries the questionable condition register.
:ENABle <value> Sets the questionable enable register.
:NTRansiton <value> Sets the Negative transition filter
:PTRansiton <value> Sets the Positive transition filter
SYSTem
:COMMunicate
:LAN|TCPip:CONTrol? Returns the initial socket control connection port number.
:RLSTate LOCal|REMote|RWLock Configures the remote/local state of the instrument.
:DATE <yyyy>, <mm>, <dd> Sets the date of the system clock.
:ERRor? Reads and clears one error from the error queue.
:LFRequency? Returns the power-line reference frequency.
:LFRequency
:MODE AUTO|MAN50|MAN60 Specifies automatic or manual line frequency detection.
:PASSword
:FPANel
:RESet Resets the front panel lockout password to zero.
:REBoot Reboots the instrument to its power-on state.
:SDS (SDS commands apply to N795xA, N796xA only)
:CONNect Connect to the SDS unit.
:MODE AUTO|MANual Selects the connection mode at power-on.
:DIGital
:DATA
:INPut? Reads the SDS digital port signals.
:OUTPut <value> Sets the SDS digital output signals.
:ENABle 0|OFF|1|ON Enables or disables the SDS unit.
:STATus? Returns the SDS status.
Keysight RP7900 Series Operating and Service Guide 31
1 Quick Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies RP7900 Series and is the answer not in the manual?

Keysight Technologies RP7900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelRP7900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals