EasyManua.ls Logo

Keysight E36300 Series - Page 79

Keysight E36300 Series
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
From the remote interface:
To configure the List voltage of output 1 with 1 V, 2 V, 3 V, 4 V and 5 V:
LIST:VOLT 1,2,3,4,5, (@1)
To configure the List current of output 1 with 0.1 A, 0.2 V, 0.3 A, 0.4 A and 0.5 A:
LIST:CURR 0.1,0.2,0.3,0.4,0.5, (@1)
To configure all the List time of output 1 with 1 s:
LIST:DWELL 1,1,1,1,1, (@1)
To enable all the List BOST of output 1:
LIST:TOUT:BOST 1,1,1,1,1, (@1)
To disable all the List EOST of output 1:
LIST:TOUT:EOST 0,0,0,0,0, (@1)
To set the voltage mode of output 1 to List:
VOLT:MODE LIST, (@1)
To set the current mode of output 1 to List:
CURR:MODE LIST, (@1)
To set the trigger source of output 1 to Key/Immediate:
TRIG:SOUR IMM, (@1)
To enable output 1:
OUTP ON, (@1)
To initiate and run the list:
INIT (@1)