8 Specifications
202 Keysight E3633A and E3634A User’s Guide
AC input ratings (selectable via rear panel selector
Maximum input power
700 VA with full load
Cooling
Fan cooled.
Operating temperature
0 to 40 °C for full rated output. At higher temperatures, the output current is
derated linearly to 50% at 55 °C maximum temperature.
Storage temperature
-20 to 70 °C for storage environment.
Environmental Conditions
Designed for indoor use in an installation category II, pollution degree 2
environment. Designed to operate at a maximum relative humidity of 95% and at
altitudes of up to 2000 meters.
Dimensions
[1]
213 mmW x 133 mmH x 348 mmD (8.4 x 5.2 x 13.7 in)
std 115 Vac ± 10%, 47 to 63 Hz
opt 0E3 230 Vac ± 10%, 47 to 63 Hz
opt 0E9 100 Vac ± 10%, 47 to 63 Hz
[1] See below for detailed information