User-Defined
Back to ARB Commands
[SOURce:]ARB:CURRent:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:CURRent:UDEFined:BOSTep[:DATA]? (@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:BOSTep[:DATA]? (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA]? (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA]? (@<chanlist>)
Specifies which user-defined Arb points or steps will generate a trigger-out signal at the beginning of
the step (BOSTep). A comma-delimited list of up to 511 steps may be programmed. The state is either
ON (1) or OFF (0). A trigger is only generated when the state is set to ON.
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
Specifies which user-defined Arb points or steps will generate a trigger-out signal at the beginning of
the step (BOSTep) for Arb sequence steps. The last value in the sequence is the step number.
Parameter Typical Return
0|OFF|1|ON, *RST 1 point with a value of Off 0or1 [,0or1]
Step 0 - 99, *RST 0 (none)
Output a trigger atthe start of the current steps: ARB:CURR:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output a trigger atthe start of the voltage steps: ARB:VOLT:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output a trigger atthe start of the power steps: ARB:POW:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output a trigger atthe start of the resistance steps: ARB:RESISTANCE:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output triggers atthe start of the steps during sequence step 0:ARB:SEQ:STEP:CURR:UDEF:BOST ON,ON,ON,ON,ON, 0,(@1)
l At the end of the user-defined Arb, the output state of the unit depends upon the ARB:TERMin-
ate:LAST program settings.
l The order in which the values are entered determines the sequence of execution.
l To create a valid user-defined Arb, the current level, voltage level, power level, resistance level,
BOST, and dwell lists must either all be the same length, or have a length of 1, which is inter-
polated as having the same length as the maximum length list.
5 SCPI Programming Reference
220 Keysight N6700C Operating and Service Guide