EasyManua.ls Logo

Keysight N6702C - Page 220

Keysight N6702C
430 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User-Defined
Back to ARB Commands
[SOURce:]ARB:CURRent:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:CURRent:UDEFined:BOSTep[:DATA]? (@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:BOSTep[:DATA]? (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA]? (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} (@<chanlist>)
[SOURce:]ARB:RESISTANCE:UDEFined:BOSTep[:DATA]? (@<chanlist>)
Specifies which user-defined Arb points or steps will generate a trigger-out signal at the beginning of
the step (BOSTep). A comma-delimited list of up to 511 steps may be programmed. The state is either
ON (1) or OFF (0). A trigger is only generated when the state is set to ON.
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:POWer:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:BOSTep[:DATA] 0|OFF|1|ON {,0or1} <step#>, (@<chanlist>)
[SOURce:]ARB:SEQuence:STEP:RESISTANCE:UDEFined:BOSTep[:DATA]? <step#>, (@<chanlist>)
Specifies which user-defined Arb points or steps will generate a trigger-out signal at the beginning of
the step (BOSTep) for Arb sequence steps. The last value in the sequence is the step number.
Parameter Typical Return
0|OFF|1|ON, *RST 1 point with a value of Off 0or1 [,0or1]
Step 0 - 99, *RST 0 (none)
Output a trigger atthe start of the current steps: ARB:CURR:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output a trigger atthe start of the voltage steps: ARB:VOLT:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output a trigger atthe start of the power steps: ARB:POW:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output a trigger atthe start of the resistance steps: ARB:RESISTANCE:UDEF:BOST ON,ON,ON,ON,ON,(@1)
Output triggers atthe start of the steps during sequence step 0:ARB:SEQ:STEP:CURR:UDEF:BOST ON,ON,ON,ON,ON, 0,(@1)
l At the end of the user-defined Arb, the output state of the unit depends upon the ARB:TERMin-
ate:LAST program settings.
l The order in which the values are entered determines the sequence of execution.
l To create a valid user-defined Arb, the current level, voltage level, power level, resistance level,
BOST, and dwell lists must either all be the same length, or have a length of 1, which is inter-
polated as having the same length as the maximum length list.