3 VMA Mode
3.9 SEM Measurement
Example
:SEM:OFFS:TYPE ETOC
:SEM:OFFS:TYPE?
Notes OFFSet1 is for BTS, 2 for MS. Default is BTS
Preset MSR: RTOCenter
LTEAFDD, LTEATDD: ETOCenter
State Saved Saved in instrument state
Range Carrier Center to Meas BW Center|Carrier Center to Meas BW Edge|Carrier Edge to Meas BW Center-
|Carrier Edge to Meas BW Edge|RF BW Edge to Meas BW Center|RF BW Edge to Meas BW Edge
Mode: 5G NR
Options: see "Mode: MSR, LTEAFDD, LTEATDD" on page 1484 above.
Remote
Command
[:SENSe]:SEMask:OFFSet[1]|2[:OUTer]:TYPE CTOCenter | CTOEdge | ETOCenter |
ETOEdge | RTOCenter | RTOEdge | RCTOCenter
[:SENSe]:SEMask:OFFSet[1]|2[:OUTer]:TYPE?
Example
:SEM:OFFS:TYPE ETOC
:SEM:OFFS:TYPE?
Notes OFFSet1 is for BTS, 2 for MS. Default is BTS
Preset
ETOCenter
State Saved Saved in instrument state
Range Carrier Center to Meas BW Center|Carrier Center to Meas BW Edge|Carrier Edge to Meas BW Center-
|Carrier Edge to Meas BW Edge|RF BW Edge to Meas BW Center|RF BW Edge to Meas BW Edge|RF BW
Center to Meas BW Center
Diagrams for Offset Freq Define
Details depend on the selected mode.
1485 Vector Modulation Analyzer Mode User's &Programmer's Reference