PAS SERIES Specifications 8-11
*6 At a measurement frequency bandwidth of 5 Hz to 1 MHz.
*7 At an ambient temperature range of 0 °C to 50 °C.
*8 The difference in the output current between the master unit and the slave unit is within
approximately 3 % of the rating.
*9 The difference in the output voltage between the master unit and the slave unit is within
approximately 3 % of the rating.
*10 Under rated load.
*11 Excludes the charge current component that flows through the capacitor of the internal
EMC filter circuit immediately after the POWER switch is turned on (within approxi-
mately 1 ms).
*12 Standard value at an input voltage of 100 VAC under rated load.
*13 At an input voltage of 100 VAC under rated load.
350W Type (cont.)
PA S
160-2
PA S
320-1
PA S
500-0.6
Output Specifications (cont.)
Current Rated output current 2.000 A 1.000 A 600.0 mA
Maximum preset current
(typ)
*1
105 % of rating
Accuracy of setting
*2
0.5 % of rating + 5 mA
*3
Source effect
*4
0.1 % of rating + 5 mA
*3
Load effect
*5
0.1 % of rating + 5 mA
*3
Ripple noise (RMS)
*6
5 mA
Temperature coefficient
(max)
*7
200 ppm/ °C
(during analog remote control)
Series/Parallel operation
Master-slave parallel operation
*8
Up to 5 units including the master
unit (same models only)
Master-slave series operation
*9
Up to 2
units
including
the master
unit
(same
models
only)
impossible
Input Specifications
Current (max)
*10
5.0 A (100 VAC)/ 2.5 A (200 VAC)
Inrush current (max)
*11
35 Apeak
Power (max)
*10
500 VA
Power factor (typ)
*12
0.980
Efficiency (min)
*13
70%