52
MIC-GAIN
Functions
Permission
Transparency
Set:
MIC-GAIN
End User
Public
Get:
MIC-GAIN?
End User
Public
Description
Syntax
Set:
Set the microphone gain
#MIC-GAINP1,P2,P3
Get:
Get the microphone gain
#MIC-GAIN?P1
Response
Set / Get: ~ nn@MIC-GAINP1,P2,␍␊
Parameters
P1 (always 0) 0
P2 - 0=Mic
P3 (level) 0 to 100
Response Triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control device
(button press, device menu and similar) or genlock status was changed
Notes
Sets the Microphone input audio gain
MIC-TLK
Functions
Permission
Transparency
Set:
MIC-TLK
End User
Public
Get:
MIC-TLK?
End User
Public
Description
Syntax
Set:
Set mic talkover parameters
#MIC-TLKchannel,P1,value
Get:
Get mic talkover parameters
#MIC-TLK?channel,P1
Response
~nn@MIC-TLK channel,P1, value␍␊
Parameters
P1 (channel) 0
P2 (parameter setting) 0=Depth, 1=Trigger, 2=Attack time, 3=Hold time, 4=Release time
P3 (value) P1 value (in corresponding to P1 units): Depth: 0~100 [%], Trigger: 0~100 (-60dB~40dB),
Attack/Hold/Release time: 0~200 (0~2 sec)