Kramer Electronics Ltd.
VP-440 Protocol 3000
51
MENU-CMD
Command Name
Permission
Transparency
Set:
MENU-CMD
End User
Public
Get:
-
-
-
Description
Syntax
Set:
This command emulates menu
navigation
# MENU-CMD param
Get:
-
-
Response
~nn@MENU-CMDparam␍␊
Parameters
param
1 - Menu
2 - OK/Enter
3 - Esc
4 - Up
5 - Down
6 - Right
7 - Left
Response Triggers
Notes
MIC-SELECT
Functions
Permission
Transparency
Set:
MIC-SELECT
End User
Public
Get:
MIC-SELECT?
End User
Public
Description
Syntax
Set:
Select the microphone.
#MIC-SELECTP1,P2
Get:
Get the active microphone.
#MIC-SELECT? P1
Response
Set / Get: ~ nn@MIC-SELECTP1,P2,␍␊
Parameters
P1 1 (Scaler)
P2 Mic mode
OFF=[]
MIC1=1
MIC2=2
Both=[1,2], [2,1]
Response Triggers
Notes