110
VP-773A - The VP-773A RS-232 Communication Protocol
PIP-MODE = Dual window state:
"0" or "off" for single window.
"1" or "on" to for dual window.
Identification commands
Command
Syntax
Response
Protocol
Handshaking
#CR
~OK CRLF
Read device model
MODEL?
MODEL MACHINE_MODEL
Read device serial
number
SN?
SN SERIAL_NUMBER
Read device
firmware version
VERSION?
VERSION MAJOR .MINOR
.BUILD .REVISION
Read device build
date
BUILD-DATE?
BUILD-DATE YYYY/MM/DD
HH:MM:SS
Read device protocol
version
PROT-VER?
PROT-VER 3000:MAJOR
.MINOR
Command - NAME
Command Type - System (Ethernet)
Command Name
Permission
Transparency
Set:
NAME
Administrator
Public
Get:
NAME?
End User
Public
Description
Syntax
Set:
Set machine (DNS) name
#NAMEmachine_name
Get:
Get machine (DNS) name
#NAME?
Response
Set: ~nn@NAMEmachine_name OK␍␊
Get: ~nn@NAME? machine_name␍␊
Parameters
machine_name - String of up to 14 alpha-numeric chars (can include hyphen, not at the
beginning or end)
Notes
The machine name is not the same as the model name. The machine name is used to
identify a specific machine or a network in use (with DNS feature on)
Network settings commands
Network settings commands require admin authorization
Command
Syntax
Response
Set IP Address
NET-IP IP_ADDRESS
NTIP
NET-IP IP_ADDRESS RESULT
Read IP
Address
NET-IP?
NTIP?
NET-IP IP_ADDRESS
Read MAC
NET-MAC?
NET-MAC MAC_ADDRESS