2 seconds, then come to
setting interface ,short press
the scroll key for more
than half a second (less than
2 seconds) to select BPS
setting, the letters “bPS”
will flash.
② Enter the BPS setting
interface. Press and hold the
function setting key for more
than half a second(less than 2
seconds) at this time, the letters
“bPS” will stop flashing. The
“ON”(or OFF) below the bPS
will flash. Press and hold the
scroll key for more than half a
second (less than 2 seconds) to
determine whether the BPS
function is enabled or disabled.
③ Confirm the BPS selecting
interface. After selecting ON
or OFF, press and hold the
function setting key for
more than half a second
(less than 2 seconds). Now,
the BPS setting function is
completed and the “ON”
or “OFF” below the
“bPS” will light without
flashing.
④ If you choose “OFF”, then
go to step 7, otherwise go
ahead to step 5.
⑤ Set the BPS tolerance
range. 0TShort press the scroll
key0T or for more than
half a second (shorter than 2
seconds)to select the
voltage range in percentage.
+5%,+10%,+15%,+25%(def
ault is +25%) , then short
press function setting key
for more than half a
second (shorter than 2
seconds)to confirm the
selection, then to set the
minus range
⑥ To set the minus range in the
same way.
⑦ After the minus range is
confirmed. Long press function
setting key for more than 2
seconds to exit setting menu.