Control box
28
Quantron S
Machine use
Adjusting the blower alarm limit values
- Starting from the "main menu", select "hopper
configuration".
- Select the "blower speed" submenu.
- Select value (1).
- Press Enter key.
- Indicate the minimum speed alarm value (see table for
values).
- Press Enter key.
- Select value (2).
- Press Enter key.
- Indicate the maximum speed alarm value (see table
for values).
It is very important to maintain the correct blower
rotational speed.
- According to the seed drill type, values are different!.
Normal use speeds
Minimum
speed
Maximum
speed
Nominal
speed
LC 302-452 3600 4500 4250
NC
3000/4000
Small grain
Large grain
2700 3300 3000
3500 4500 4200
Moduliner-
Solo
2800 3500 3200
TF 702
Small grain
2000 2800 2500
Large grain 2800 3500 3200
MEGANT 2800 3500 3200
Respect the indicated values. In case of
excessive speed, there are risks of damaging
the machine.