41 / 93Issued: 20.04.2018 Version: Spez KR C4 compact V10
5 Safety
smartPAD The user must ensure that the industrial robot is only operated with the smart-
PAD by authorized persons.
If more than one smartPAD is used in the overall system, it must be ensured 
that it is clearly recognizable which smartPAD is connected to which industrial 
robot. They must not be interchanged.
Modifications After modifications to the industrial robot, checks must be carried out to ensure 
the required safety level. The valid national or regional work safety regulations 
must be observed for this check. The correct functioning of all safety functions 
must also be tested.
New or modified programs must always be tested first in Manual Reduced Ve-
locity mode (T1).
After modifications to the industrial robot, existing programs must always be 
tested first in Manual Reduced Velocity mode (T1). This applies to all compo-
nents of the industrial robot and includes e.g. modifications of the external 
axes or to the software and configuration settings.
Faults The following tasks must be carried out in the case of faults in the industrial 
robot:
 Switch off the robot controller and secure it (e.g. with a padlock) to prevent 
unauthorized persons from switching it on again. 
 Indicate the fault by means of a label with a corresponding warning (tag-
out).
 Keep a record of the faults.
 Eliminate the fault and carry out a function test.
5.8.2 Transportation
Manipulator The prescribed transport position of the manipulator must be observed. Trans-
portation must be carried out in accordance with the operating instructions or 
assembly instructions of the robot.
Avoid vibrations and impacts during transportation in order to prevent damage 
to the manipulator.
Robot controller The prescribed transport position of the robot controller must be observed. 
Transportation must be carried out in accordance with the operating instruc-
tions or assembly instructions of the robot controller.
Standing underneath the robot arm can cause death or 
injuries. For this reason, standing underneath the robot 
arm is prohibited!
The motors reach temperatures during operation which 
can cause burns to the skin. Contact must be avoided. 
Appropriate safety precautions must be taken, e.g. protective gloves must be 
worn.
The operator must ensure that decoupled smartPADs 
are immediately removed from the system and stored out 
of sight and reach of personnel working on the industrial robot. This serves 
to prevent operational and non-operational EMERGENCY STOP devices 
from becoming interchanged.
Failure to observe this precaution may result in death, severe injuries or con-
siderable damage to property.