8-57
System Menu > [Date/Timer/Energy Saver]
Sleep Level (models except for
Europe)
*1
Select the sleep level.
Set the Energy Saver mode to reduce power consumption even more than normal
Sleep mode.
Value: Quick Recovery, Energy Saver
This function will not be displayed when the optional Network Interface Kit is installed.
Sleep Rules Select whether to use the Energy Saver mode for the following functions individually:
Card Reader
*2
Application
Value: Off, On
When the machine has entered sleep mode with Energy Saver setting, it does not wake
from sleep mode when it receives print data from a PC connected by USB cable. Also,
the ID card cannot be recognized.
Sleep Timer Set amount of time before entering Sleep.
Value:
ECOSYS M4125idn for Europe: 1 to 60 minutes (1 minute increments)
ECOSYS M4132idn for Europe: 1 to 120 minutes (1 minute increments)
Except for Europe 1 to 240 minutes (1 minute increments)
Energy Saver Recovery Level Select the method of recovery from energy saver.
Value
Full Recovery: This mode enables the use of all functions immediately.However, this
mode saves less energy.
Normal Recovery: In this mode, you can select the method from the following: enabling
the use of all functions immediately or enabling the use of desired functions only.If you
want to use all functions immediately, select the [Energy Saver] key to execute recovery.
Power Saving Recovery: This mode enables the use of desired functions only. This
mode saves energy most effectively.
Auto Error Clear If an error occurs during processing, processing stops to wait for the next step to be
taken by the user. In the Auto Error Clear mode, automatically clear the error after a set
amount of time elapses.
Value: Off, On
For setting the automatic error recovery time, refer to the following item.
Error Clear Timer If you select [On] for Auto Error Clear, set the amount of time to wait before
automatically clearing errors.
Value: 5 to 495 seconds (in 5 second increments)
This function is displayed when [Auto Error Clear] is set to [On].
Interrupt Clear Timer Set the period after which the machine reverts to Normal mode when it has been set to
Interrupt Copy mode and then left unused.
Value: 5 to 495 seconds (in 5 second increments)
Item Description