2RV/2RW/2RX/2RY/3RA
9-3
Vertical offset (100 V model only)* K2 -7 to +7 (Integer), unit: cm 0
K3 -99 to +99 (Decimal), unit: 1/100 cm 0
Kanji font number setting
(100 V model only)
K4 0: Same as V7
1: Mincho 40 dots
2: Gothic 40 dots
5: Mincho 48 dots
6: Gothic 48 dots
0
New/old JIS code switching
(100 V model only)
K6 0: JIS X 0208: 1990
1: JIS X 0208: 1978
8: JIS X 0213: 2004
0
Duplex printing mode selection N4 0: OFF
1: Long-edge mode (long-edge bind)
2: Short-edge mode (Short-edge bind)
0
Sleep timer time-out time N5 1 to 240 minutes 1
Ecoprint level N6 0: OFF
2: ON
0
Default emulation mode P1 6 : PCL6
9 : KPDL
6
9: 120V
Carriage-return action P2 0: Ignores
1: CR
2: CR+LF?
1
Linefeed action P3 0: Ignores
1: LF
2: CR+LF?
1
KPDL auto switching P4 0: None
1: Auto switching
0
1(120V
model)
AES option
Page eject command and action
when automatic emulation switch-
ing (AES) is triggered
P7 If the data is neither applicable to KPDL nor
alternate emulation after the AES is started, it
is processed in the alternate emulation .
0: All page eject commands
1: None
2: All page eject commands and Prescribe
EXIT command
3: Prescribe EXIT command only
4: ^L command only
6: Prescribe EXIT command and ^L command
If the data is neither applicable to KPDL nor
alternate emulation after the AES is started, it
is processed in KPDL.
10: Data other than KPDL print data is printed
in the alternate emulation.
10
11: 120V
Command recognition character P9 ASCII code of 33 to 126 82(R)