2WA/2NJ/2RK
6-263
Setting: Cnt
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key to set the setting value.
Setting: Setting
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Items Contents Setting
range
Initial setting
Detect Black
Line(CCD)
DP(CCD side)streak detection 0 to 999999 0
Detect White
Line(CIS)
DP(CIS side)white streak detection 0 to 999999 0
Table Scan Table Scan sheet number 0 to 999999 0
Unit Per DP Cnt(B) Error Counts Per Unit(DP back side of
black streak)
0 to 999999 0
Error Defined sheet error counts of notice
number
0 to 999999 0
Items Contents Setting
range
Initial setting
Removal Of Black
Line(F)
Setting of line removal strong(DP face
side of black line)
5 to 15 15
Removal Of Black
Line(B)
Setting of line removal strong(DP face
back of black line)
5 to 15 15
Rate Of Alert(F) Rate of alert detection[%](DP face side
of black line)
0 to 20 1
Rate Of Alert(B) Rate of alert detection[%](DP face back
side of black line)
0 to 20 1
Unit Per Sheet Num(F) Unit Per Sheet Number(Face side) 300/500/1000 1000
Unit Per Sheet
Num(B)
Unit Per Sheet Number(Back side) 300/500/1000 1000