Corrective maintenance
Preparing enclosures for maintenance
Most maintenance procedures require L2-CHARIOT/L2D-CHARIOT to be removed. This means that the enclosures, in
particular L2D, may need to be turned upside-down using L2-ROLL.
Rigging accessories
L2-RIGBAR
BPCHAIN 1.5T
L2-ROLL
Tools
screwdriver
8 mm hex bit
Do not use L2-ROLL for rigging.
L2-ROLL is a temporary handling tool, not a long-term rigging accessory.
Never position L2D on its narrow edge, even temporarily.
Prerequisite
L2-CHARIOTLID/L2D-CHARIOTLID and
L2-CHARIOTCOV/L2D-CHARIOTCOV are
removed.
See Mounting L2-CHARIOTLID/L2D-CHARIOTLID on L2/L2D (p.136)
Inspect L2-ROLL before use.
Do not use if any safety issue is detected during inspection (fraying, deformation, etc.).
Procedure
1. Make sure each strap is secured to one ring with a lark's head knot.