106 Operating the AUTOMIZER
TM
HELPING-HAND
Water Trap Bleeding
Usually located on the right-hand side truck frame, near mid-section, the water trap must be drained
at the end of every working day. Just slacken off both water trap bleed screws under the bowls and
catch the water and oil that flow out with a rag. The water trap helps keep moisture out of the air
system.
Figure 4-18
Water trap
Troubleshooting Quick Reference
If an electrical failure occurs and prevents the operator from retracting the arm, the following
procedure can be applied:
1. Set the parking brake and put the transmission to neutral.
2. Install a control lever on the arm extend/retract section of the proportional valve (see Figure
4-19 and Figure 4-20) located on the left-hand side of the vehicle. With this lever retract the arm
slowly until it reaches its home position.
Danger!
Stay clear of the path of the arm at all times and do not open the gripper in mid-air when
performing this procedure.
Screws
Bowls